文章摘要
王轶禹,马世俊,皮俊波,等.关于国调直调电厂“两个细则”的讨论[J].电力系统自动化,2018,42(16):174-179. DOI: 10.7500/AEPS20180301006.
WANG Yiyu,MA Shijun,PI Junbo, et al.Discussion on “Two Rules” of Power Plants Directly Dispatched by State Grid Electric Power Dispatching and Control Center[J].Automation of Electric Power Systems,2018,42(16):174-179. DOI: 10.7500/AEPS20180301006.
关于国调直调电厂“两个细则”的讨论
Discussion on “Two Rules” of Power Plants Directly Dispatched by State Grid Electric Power Dispatching and Control Center
DOI:10.7500/AEPS20180301006
关键词: 直调电厂  运行模式  发电厂并网运行  辅助服务  管理实施细则
KeyWords: direct dispatching power plant  operation modes  grid-connected operation of power plants  ancillary services  management implementation rules
上网日期:2018-06-26
基金项目:
作者单位E-mail
王轶禹 国家电网有限公司国家电力调度控制中心, 北京市 100031  
马世俊 中国电力科学研究院有限公司, 北京市 100192 iammashijun@163.com 
皮俊波 国家电网有限公司国家电力调度控制中心, 北京市 100031  
王春明 国家电网华中电力调控分中心, 湖北省武汉市 430077  
张健 中国电力科学研究院有限公司, 北京市 100192  
李文锋 中国电力科学研究院有限公司, 北京市 100192  
摘要:
      目前,《发电厂并网运行管理实施细则》和《并网发电厂辅助服务管理实施细则》正在中国几个区域电力系统逐步实施。为促进国调直调电厂管理的规范化、制度化,保障电网安全、优质、经济运行,维护电力企业合法权益,有必要针对国调直调电厂进行“两个细则”的编制。首先针对国调直调电厂“两个细则”下的运行模式进行了研究,对国调直调电厂“两个细则”下各种可行运行模式的优缺点进行了详尽的讨论;其次根据国调直调电厂的实际情况,提出了适应直调电厂的“两个细则”的具体建议;最后根据实际算例,验证了所提建议的合理性。
Abstract:
      At present, the “Two Rules”, i. e. , the management of the grid-connected operation of the power plants and the management of ancillary services, are being progressively enforced in several regional power systems in China. In order to promote the standardization and institutionalization of the management of direct dispatching power plant by State Grid Electric Power Dispatching and Control Center, ensure the safety, high quality and economic operation of power grids, and safeguard the legitimate rights and interests of power enterprises, it is necessary to formulate the “Two Rules” for the power plants directly dispatched by State Grid Electric Power Dispatching and Control Center. The operation mode is studied under the “Two Rules” and the advantages and disadvantages of various feasible operation modes are discussed. Secondly, some concrete suggestions are put forward on how to implement the “Two Rules” according to the actual situation of the power plants directly dispatched by State Grid Electric Power Dispatching and Control Center. Finally, the rationality of the proposals is verified according to the actual examples.