弱电网下计及直流同步特性的跟网型变流器自适应控制策略
作者:
作者单位:

哈尔滨工业大学电气工程及自动化学院,黑龙江省哈尔滨市 150000

摘要:

弱电网下,跟网型变流器因锁相环与电网阻抗的交互作用,易引发振荡失稳问题,而构网型技术中直流电压同步控制方法能利用直流动态模拟发电机功角特性,从而实现自主同步,具有更强的稳定性。文中通过对比发电机转子运动方程与直流电压同步控制结构,提出弱电网下计及直流同步特性的跟网型变流器自适应控制策略。该策略将直流动态偏差引入锁相环同步环节,并采用权重系数分配实现2种方法的协调融合,使变流器在弱电网下具备构网型控制的稳定优点。在此基础上,基于系统阻尼特性设计权重系数,揭示其与电网阻抗的关联性;进一步,结合阻抗在线辨识技术,实现参数自适应调整。序阻抗模型分析表明,所提策略可有效抑制弱电网下跟网型变流器的次同步振荡。最后,通过实验验证了所提方法的有效性。

关键词:

基金项目:

国家自然科学基金资助项目(51977046)。

通信作者:

作者简介:

易传卓(1998—),男,博士研究生,主要研究方向:新能源并网控制与建模分析。E-mail:yichuanzhuo@163.com
张学广(1981—),男,通信作者,教授,博士生导师,主要研究方向:新能源发电技术与大功率电力电子技术。E-mail:zxghit@126.com
徐殿国(1960—),男,教授,博士生导师,主要研究方向:交流电机无传感器控制、交流伺服系统、电力电子化电力系统等。E-mail:xudiang@hit.edu.cn


Adaptive Control Strategy for Grid-following Converter Considering DC Synchronization Characteristics in Weak Grid
Author:
Affiliation:

School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin 150000, China

Abstract:

In a weak grid, grid-following converters are prone to oscillation instability due to the interaction between the phase-locked loop (PLL) and the grid impedance. However, the DC voltage synchronization control method in the grid-forming technology can achieve autonomous synchronization by utilizing DC dynamics to emulate generator power angle characteristics, offering enhanced stability. By comparing the generator rotor motion equation with the DC voltage synchronization control structure, this paper proposes an adaptive control strategy for the grid-following converter in a weak grid, considering DC synchronization characteristics. This strategy introduces the DC dynamic deviation into the PLL synchronization link and employs weight coefficient allocation to achieve coordinated integration of both methods, enabling the converter to possess the stability advantages of the grid-forming control in weak grids. On this basis, the weight coefficients are designed according to system damping characteristics, and their correlation with the grid impedance is revealed. Further, the adaptive parameter adjustment is realized by integrating the online impedance identification technology. The sequence impedance model analysis shows that the proposed strategy can effectively suppress the sub-synchronous oscillation of grid-following converters in weak grids. Finally, the effectiveness of the proposed method is verified through experiments.

Keywords:

Foundation:
This work is supported by National Natural Science Foundation of China (No. 51977046).
引用本文
[1]易传卓,张学广,徐殿国.弱电网下计及直流同步特性的跟网型变流器自适应控制策略[J].电力系统自动化,2026,50(9):212-221.
YI Chuanzhuo, ZHANG Xueguang, XU Dianguo. Adaptive Control Strategy for Grid-following Converter Considering DC Synchronization Characteristics in Weak Grid[J]. Automation of Electric Power Systems, 2026, 50(9):212-221.